MST-406EN Automotive Emission Analyzer(4-Gas / Portable)
Main Features and Specifications
1. Measure concentration of HC, CO, CO2, O2 contained in exhaust gases from gasoline engine of vehicles. Advanced NDIR (non-Dispersive Infrared) analysis technology is used to measure HC, CO, CO2 and the newest generation of electrochemical technology is adopted to measure O2 . Designed with LCD screen for easier setting and operation.
2. Automatic calculation and display of A/F (air-fuel-ratio)
and Lambda air ratio .
3. Emissions from vehicle engine fuels of CNG, LPG and Ethanol gasoline can be measured.
4. Small Size, light weight and most convenient for carry.
5. Designed with inductive clip-on pickup sensor for RPM
measurement.
6. Designed with oil temperature measurement probe.
6. Designed with RS-232C digital serial interface.
7. 200 groups of measurement data storage and review.
8. In compliance with accuracy requirement of ISO 3930
or OIML R99 Class I.
Options and Accessories:
1. Micro printer.
2. Various RPM measurement adaptors.
3. DC12V vehicle power inverter.
Main Technical Specifications
Measuring Range:
HC: 09,999 ppm (n-Hexane)
CO: 010 %
CO2 : 018 % 2
O2 : 025 % 2
Measurement Accuracy:
HC: ±12 ppm (abs.) 02,000 ppm
±5 % ( rel. ) 02,000 ppm (which ever is larger)
±10 % ( rel. ) 2,0019,999 ppm
CO: ±0.06 % (abs.)
±5 % ( rel. ) (which ever is larger)
CO2 : ±0.5 % (abs.)
±5 % ( rel. ) (which ever is larger)
O2 : ±0.1 % (abs.)
±5 % ( rel. ) (which ever is larger)
Response Time: Less than 10s for T90
(O2, less than 12s)
Warm-up Time: 10 min.
(ambient temperature is not lower than 20)
Power Supply: AC220V ±10% 50Hz ±1Hz
Net Weight: 6.0Kg
Outer Dimension:
260mm(W) × 180mm(H) × 450mm(D)
Related Product Tags:
adaptor , adaptors , auto adaptor , auto adaptor asm , Cigarette Lighter Adaptor , tv adaptor , airbag reset , airbag resetting , vag airbag reset tool , srs airbag reset , airbag reset tool , oil light airbag reset tool , mb airbag reset tool , airbag reseter , analyze , Battery Detector , Beepro Programmer , boost