ZL0302 Oil pressure gauge High quality gauges that are designed to perform in bugged applications and harsh environment, especially in easy pulsation and vibration Media is not corrosive to brass Type: liquid filled pressure gauges Case material: 304 stainless steel case, it can take with back flange Case size: 1.5, 2, 2.5, 3, 4 and 6 inches Bezel material: stainless steel bezel Tube and socket: brass Connection: 1/8, 1/4, 3/8 and 1/2 inches BSP, NPT or BSPT Type: bottom and back Scale ranges: -1 to 0 to 600bar Window material: PC and anti-explosion Accuracy: 1.0, 1.6 and 2.5; ZL0302 Oil Pressure Gauge with Stainless Steel Case, Made of Stainless Steel Bezel
D86three-phase watt-hour meter Application D86 series three-phase watt-hour meter are induction meters which are applicable to measure the rated frequency 50Hz or 60Hz and power loss of active energy meter. The series active energy meters are completely conformed to National Standard GB/T15283-94 and International Standard IEC60521. All technical targets of reactive energy meter are completely conformed to National Standard GB/T15282-94 and International Standard IEC60145. Brief Technical Data Name Type Accuracy Rated voltage(V) Rated current(A) Connection Mode Three-phase energy watt-hour meter DT862 Class 2 3×380/220 3×100/57.5 3×X/5 Input through current transformer Three-phase energy watt-hour meter DT862 Class 2 3×380/220 3×100/57.5 3×5(20), 3×10(40), 3×15(60), 3×30(100) Directly input Three-phase active energy watt-hour meter DT864 Class 1 3×380/220 3×100/57.5 3×X/5 Input through current voltage transformer Three-phase active energy watt-hour meter DS862 Class 2 3×380 3×5(20), 3×10(40), 3×15(60), 3×30(100) Directly input Three-phase active energy watt-hour meter DS862 Class 2 3×380 3×100 3×X/5 Input through current voltage transformer Three-phase active energy watt-hour meter DS864 Class 1 3×380 3×100 3×X/5 Input through current transformer Three-phase reactive energy watt-hour meter DX862 Class 3 3×380 3×100 3×X/5 Input through current voltage transformer Three-phase reactive energy watt-hour meter DX864 Class 2 3×380 3×100 3×X/5 Input through current voltage transformer Three-phase reactive energy watt-hour meter DX865 Class3 3×380 3×100 3×X/5 Input through current voltage transformer Three-phase reactive energy watt-hour meter DX863 Class 2 3×380 3×100 3×X/5 Input through current voltage transformer SONGXIA 3P meter(electric meter, energy meter,kwh meter); IEC60521,5+1digits/5 digits register;optional Case Materials
FEATURESConform to the IEC1010-1 standard CAT III 600V and CAT II 1000VSound & light warning for the incorrect inserting the input plugSMT applicationDisplay: 3999 countsDC voltage: 400m/4/40/400V±0.7%, 1000V±0.8%AC voltage: 400mV±3.0%, 4/40/400V±0.8%, 750V±1.0%DC current: 400μ/4000μ/40m/400mA±1.2%, 10A±2.0%AC current: 400μ/4000μ/40m/400mA±1.5%, 10A±3.0%Resistance: 400/4k/40k/400k/4MΩ±1.2%, 40MΩ±2.0%Capacitance: 4nF±5.0%, 40n/400n/4μ/40μ/200μF±3.0%Frequency: 10/100/1000/10k/200kHz±2.0%hFE: 1~1000Diode testContinuity testDuty cycle testRelative measurementAuto power offResettable fuse insideData holdBack lightPower: AAA (1.5V) x 3Size: 195mm x 92mm x 55mmWeight: Approx. 380g(including battery) AUTORANGE DIGITAL MULTIMETER
D86 series three-phase watt-hour meter(energy meter,KWH meter,digital meter,electric meter) D86three-phase watt-hour meter Application D86 series three-phase watt-hour meter are induction meters which are applicable to measure the rated frequency 50Hz or 60Hz and power loss of active energy meter. The series active energy meters are completely conformed to National Standard GB/T15283-94 and International Standard IEC60521. All technical targets of reactive energy meter are completely conformed to National Standard GB/T15282-94 and International Standard IEC60145. Brief Technical Data Name Type Accuracy Rated voltage(V) Rated current(A) Connection Mode Three-phase energy watt-hour meter DT862 Class 2 3×380/220 3×100/57.5 3×X/5 Input through current transformer Three-phase energy watt-hour meter DT862 Class 2 3×380/220 3×100/57.5 3×5(20), 3×10(40), 3×15(60), 3×30(100) Directly input Three-phase active energy watt-hour meter DT864 Class 1 3×380/220 3×100/57.5 3×X/5 Input through current voltage transformer Three-phase active energy watt-hour meter DS862 Class 2 3×380 3×5(20), 3×10(40), 3×15(60), 3×30(100) Directly input Three-phase active energy watt-hour meter DS862 Class 2 3×380 3×100 3×X/5 Input through current voltage transformer Three-phase active energy watt-hour meter DS864 Class 1 3×380 3×100 3×X/5 Input through current transformer Three-phase reactive energy watt-hour meter DX862 Class 3 3×380 3×100 3×X/5 Input through current voltage transformer Three-phase reactive energy watt-hour meter DX864 Class 2 3×380 3×100 3×X/5 Input through current voltage transformer Three-phase reactive energy watt-hour meter DX865 Class3 3×380 3×100 3×X/5 Input through current voltage transformer Three-phase reactive energy watt-hour meter DX863 Class 2 3×380 3×100 3×X/5 Input through current voltage transformer SONGXIA three-phase meter ;5+1 digits or 6 digits register;bearing:dual jewel,magnetic thrust or magnetic float;optional cases
pressure gage Case size: 2.5, 4 inches Case material: 304SS Tube and socket: brass and phosphor bronze Connection: 1/4, 1/2, 3/8 inches, NPT, BSP or BSPT Type: bottom or back Scale range: -1 to 0 to 600 bars Windows: acrylic, glass, anti-explosion and polycarbonate lens available Accuracy: 1.0, 1.6 and 2.5 pressure gage with Stainless Steel Case, Brass Internal, and Connection
SONGXIA D86Series three-phase watt-hour meter(energy meter, kwh meter, electric meter) D86three-phase watt-hour meter Application D86 series three-phase watt-hour meter are induction meters which are applicable to measure the rated frequency 50Hz or 60Hz and power loss of active energy meter. The series active energy meters are completely conformed to National Standard GB/T15283-94 and International Standard IEC60521. All technical targets of reactive energy meter are completely conformed to National Standard GB/T15282-94 and International Standard IEC60145. Brief Techinical Data: Name Type Accuracy Rated voltage(V) Rated current(A) Connection Mode Three-phase energy watt-hour meter DT862 Class 2 3×380/220 3×100/57.5 3×X/5 Input through current transformer Three-phase energy watt-hour meter DT862 Class 2 3×380/220 3×100/57.5 3×5(20), 3×10(40), 3×15(60), 3×30(100) Directly input Three-phase active energy watt-hour meter DT864 Class 1 3×380/220 3×100/57.5 3×X/5 Input through current voltage transformer Three-phase active energy watt-hour meter DS862 Class 2 3×380 3×5(20), 3×10(40), 3×15(60), 3×30(100) Directly input Three-phase active energy watt-hour meter DS862 Class 2 3×380 3×100 3×X/5 Input through current voltage transformer Three-phase active energy watt-hour meter DS864 Class 1 3×380 3×100 3×X/5 Input through current transformer Three-phase reactive energy watt-hour meter DX862 Class 3 3×380 3×100 3×X/5 Input through current voltage transformer Three-phase reactive energy watt-hour meter DX864 Class 2 3×380 3×100 3×X/5 Input through current voltage transformer Three-phase reactive energy watt-hour meter DX865 Class3 3×380 3×100 3×X/5 Input through current voltage transformer Three-phase reactive energy watt-hour meter DX863 Class 2 3×380 3×100 3×X/5 Input through current voltage transformer SONGXIA watt-hour meter IEC60521Standard, Semi Closed Core Structure, 5+1digits/5 digits register, Optional Case Material
DD722 is Active Single-phase Long Life Watt-hour Meter(meter,energy meter,kwh meter).It is used to measure the power consumption in the Single-phase AC Power Grid. The advanced technology to prolong meter's life is adopted in the manufacturing. It is of 5+1 digits or 5 digits register. The customers can select different material for the case structure. They can be bakelite, PC, ABS plastic, glass and aluminum. Brief Technical Data: Accuracy Rated Voltage(V) Rated Current (A) Overload Capacity Starting Current Power Loss in Circuit Usage Life (Year) 2 Class 220-240 1.5(6), 2.5(10), 5(20)10(40), 15(60),20(80), 5(30),10(60) 4-6Ib SONGXIA 1P Long Life Active Meter(energy meter,kwh meter) IEC60521; 1. Optional Case Material; 2. 5+1digits or 5 digits align="center" 0.5%Ib ≤1.0W 5VA 30
pressure gauge lower mount connection accuracy:3-2-3% connection:7/16",5/16",1/8",1/4",3/8",1/2"NPT,BSP,BSPT dia size:1.5" 2" 2.5" 3" 3.5" 4" 4.5" 6" use:measuring pressure on copper and copper alloy non-corrosive,non-explosive,non-crystalline,not precipitate the gas or liquid pressure.Such as water and air. pressure gauge lower mount connection safety glass high quality competitive price